Features:
|
Features: |
|
Description: The Sy629VME-CP-M card provides a convenient means for monitoring ARINC 629 bus traffic, while transmitting and receiving data in accordance with programme data written into the XPP and RPP personality memory. The design provides the capability to transmit messages under Basic Protocol (BP) or Combined Protocol (CP). This is achieved using two terminal controllers, one handling the periodic messages associated with Basic Protocol and the second terminal controller handling the aperiodic messages associated with Combined Protocol. This card is a module fit to the Sy629VME-BP-M and therefore includes many of the features associated with full bus monitoring. The use of the recognised DATAC chip ensures full compliance with ARINC 629 specification with Basic Protocol (BP). |
![]() |
|
Specification: |
|
|
Power Requirements (maximum) |
+ 5V at 2.5 A |
|
Address Selection |
Addressable on 128k boundaries |
|
VME Interface |
A24, A32, D16 |
|
Connector Type |
DIN 41612, P1-96 pin, P2-96 pin |
|
Input/Output Connector |
Outer rows of P2 and Front Panel D-Type connectors |
|
Operating Temperature |
0° C to + 70° C |
|
Storage Temperature |
- 25° C to + 85° C |
|
Relative Humidity |
0 to 95% (non condensing) |
|
|
Ordering Information and Variants: |
|
Sy629VME-CP-M : |
ARINC-629 to VMEbus interface. BP/CP Protocol, Transmitter & Full Bus Monitor |
|
ARINC-629 to VMEbus interface. Transmitter & Full Bus Monitor under Basic Protocol (BP) |
|
|
ARINC-629 to VMEbus interface. Transmitter & Full Bus Monitor under BP. Conduction Cooled |
|
|
ARINC-629 to VMEbus interface. Basic Protocol (BP), Error Insert & Detect Module |
|
|
ARINC-629 to VMEbus interface. Basic Protocol (BP), Multi-Terminal Emulation |
|
|
ARINC-629 to VME/VSBbus interface. BP/CP Protocol, uses MCE chip set |
|
|
ARINC-629 to VME/VSBbus interface. BP/CP Protocol, uses MCE chip set. Error Insertion & Detection Module |
Request more information
|
Contact Details: |
|
Sycos AES |
|
|
|
If you have any comments on our web-page design, please E-mail us at webmaster@sycos.co.uk. |