Features:

   Bullet 1 - Click image to download. Uses DATAC chip

   Bullet 1 - Click image to download. Direct access to XPP & RPP

   Bullet 1 - Click image to download. Block & Independent Modes

   Bullet 1 - Click image to download. Multiple Dual Data Buffers

   Bullet 1 - Click image to download. High Resolution System Timer

   Bullet 1 - Click image to download. Cyclic Redundancy Checking (CRC)

   Bullet 1 - Click image to download. Optional Conduction Cooled Version

 

    Features:

   Bullet 1 - Click image to download. Bus Monitoring including:

   Bullet 1 - Click image to download. Label & Extension

   Bullet 1 - Click image to download. Time stamping

   Bullet 1 - Click image to download. Error Status

   Bullet 1 - Click image to download. Word & Word-String Count

   Bullet 1 - Click image to download. External Timer Clock input

   Bullet 1 - Click image to download. Multiple XPP

 
Description:

The Sy629PC-BP-M card provides a convenient means for transmitting and receiving data over an ARINC 629 bus in accordance with the transmit and receive programme defined by data written into the XPP and RPP memory. The card uses the DATAC terminal controller for scheduling messages onto the bus and receiving messages from the bus, via the System Interface Module (SIM), using Basic Protocol. The RPP provides message filtering from the bus.

The card has a facility to automatically decode received messages and time-stamp them with resolution of 0.5 µS. A Status FIFO is used to store information about received messages, including Label+Extension, 32-bit time-stamp, Word Count and String Count and DATAC Error Status. Received Data can be directed to either a dual data buffer or FIFO or both. A Receive Monitor enables the user to capture all bus traffic, irrespective of programming the RPP. This can be extremely useful if there is little knowledge of messages on the bus. A Transmit Monitor is available for monitoring all transmit messages. A Dual Data Buffer is used for loading messages for transmission. Only one side of the buffer is active to the DATAC, whilst new messages are loaded into the dormant side of the buffer. This preserves message integrity. The Dual Data Buffer is also used for receiving complete messages from the bus.

 

 

Specification:

 

Power Requirements (maximum)

+   5V at 2.5 A
+ 15V at 400 mA
-  15V at 400 mA

Address Selection

I/O Addressable in 32 byte blocks

Memory Addressable on 32k or 256k boundaries, depending upon configuration

PC-AT Interface

A24, D16

Input/Output Connector Type

25-pin 'D' Type and 9-pin 'D' Type

Operating Temperature

   0° C to + 70° C

Storage Temperature

- 25° C to + 85° C

Relative Humidity

 0 to 95% (non condensing)

 

 

Ordering Information and Variants:

 Sy629PC-BP-M :

 ARINC-629 to PC-ATbus interface. Transmitter & Full Bus Monitor under Basic Protocol (BP)

 Sy629PC-BP-E :

Error Insertion & Detection Module. Basic Protocol (BP)

 Sy629PC-BP-T :

 ARINC-629 to PC-ATbus interface, Basic Protocol (BP), Multi-Terminal Emulation

 Sy629PC-MCE :

 ARINC-629 to PC-ATbus interface. BP/CP Protocol, uses MCE chip set

 Sy629PC-MCE-E :

 Error Insertion & Detection Module. BP/CP Protocol, uses MCE chip set.

 Request more information

 

BACK to Sycos Home Page

 

Contact Details:

 
 

Sycos AES
Hambledon Manor, Iwerne Minster, Blandford Forum, Dorset, England. DT11 8QS
Tel:   +44 (0) 1747 812 486
Fax: +44 (0) 1747 812 486
SYCOS Copyright © 2006

 
 

 

 If you have any comments on our web-page design, please E-mail us at webmaster@sycos.co.uk.