Description: The Sy629PC-BP-T card is an ARINC 629 to PC-ATbus interface that provides a cost effective means for emulating up to 120 ARINC 629 Terminals, transmission and reception, with full data bus monitoring. With a single connection to an ARINC 629 data bus, the card provides facilities to add and delete terminals to/from the bus 'on-the-fly', whilst preserving the protocol. Emulated terminals compete with true terminals for bus access, in accordance with Basic Protocol. Important features such as refresh counter support and CRC checking are embedded in the design.
|
|
Specification: |
|
|
Power Requirements (maximum) |
+ 5V at 2.5 A |
|
Address Selection |
I/O Addressable in 32 byte blocks Memory Addressable on 32k or 256k boundaries, depending upon configuration |
|
PC-AT Interface |
A24, D16 |
|
Input/Output Connector Type |
25-pin 'D' Type and 9-pin 'D' Type |
|
Operating Temperature |
0° C to + 70° C |
|
Storage Temperature |
- 25° C to + 85° C |
|
Relative Humidity |
0 to 95% (non condensing) |
|
|
Ordering Information and Variants: |
|
Sy629PC-BP-T : |
ARINC-629 to PC-ATbus interface, Basic Protocol (BP), Multi-Terminal Emulation |
|
ARINC-629 to PC-ATbus interface. Transmitter & Full Bus Monitor under Basic Protocol (BP) |
|
|
Error Insertion & Detection Module. Basic Protocol (BP) |
|
|
ARINC-629 to PC-ATbus interface. BP/CP Protocol, uses MCE chip set |
|
|
Error Insertion & Detection Module. BP/CP Protocol, uses MCE chip set. |
Request more information
|
Contact Details: |
|
Sycos AES |
|
|
|
If you have any comments on our web-page design, please E-mail us at webmaster@sycos.co.uk. |